Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.886
Filtrar
2.
Chest ; 160(3): e265-e268, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34488965

RESUMO

CASE PRESENTATION: A 70-year-old woman was transferred to our ED from an outside ED for hypoxemia. Three weeks earlier, an inpatient evaluation for syncope revealed a right intraventricular filling defect, multiple pulmonary nodules, pulmonary emboli, and a left breast mass. She underwent breast biopsy, was started on rivaroxaban, and was discharged with outpatient follow-up. She experienced progressively worsening dyspnea, prompting a return to the outside ED, where she was found to be severely hypoxemic and was intubated. Her medical history included diabetes, hypertension, hyperlipidemia, COPD, hypothyroidism, diastolic heart failure, and a 40+ pack-year smoking history.


Assuntos
Cateterismo Cardíaco , Forame Oval Patente , Neoplasias Cardíacas , Comunicação Interatrial , Hipóxia , Complicações Intraoperatórias/diagnóstico , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Embolia Pulmonar , Radiografia Torácica/métodos , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Diagnóstico Diferencial , Ecocardiografia/métodos , Evolução Fatal , Feminino , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/patologia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Hipóxia/diagnóstico , Hipóxia/etiologia , Hipóxia/fisiopatologia , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/etiologia , Síncope/diagnóstico , Síncope/etiologia , Tomografia Computadorizada por Raios X/métodos
3.
Circ Cardiovasc Imaging ; 14(8): e012371, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34384233

RESUMO

BACKGROUND: Partial anomalous venous connections (PAPVC) are associated with left to right shunting and right heart dilatation. Identification of PAPVC has increased with widespread use of cross-sectional imaging modalities. However, management strategies are mostly based on expert opinion given the scarcity of data from large series. We aimed to define types and significance of isolated and atrial septal defect (ASD) associated PAPVC detected by cardiovascular magnetic resonance. METHODS: We retrospectively reviewed our cardiovascular magnetic resonance database from 2002 to 2018 to identify isolated or ASD-associated PAPVC cases. RESULTS: A total of 215 patients (median age 46 years; range, 6-83) with isolated or ASD-associated PAPVC were identified among 102 135 clinical cardiovascular magnetic resonance studies. Of these, 104 were isolated and 111 were associated with an ASD. Anomalous connection of right upper pulmonary vein was the most common single venous anomaly (99/215), but in the isolated PAPVC group there were more anomalous left than right upper pulmonary veins (39 versus 34). The Qp/Qs was significantly higher for isolated anomalous single right upper pulmonary vein than left upper pulmonary vein (1.6 versus 1.4 respectively; P=0.01) as were right ventricular end-diastolic volumes (113.7±30.9 versus 90 [57-157] mL/m2, P=0.004). In the PAPVC with an ASD group, sinus venosus ASDs (82%) were associated with right-sided PAPVCs while both right and left-sided venous anomalies were seen in secundum ASDs (18%). In a substantial number of patients (30 out of 91) with sinus venosus ASDs, PAPVCs were more complex and involved more than a single anomalous right upper pulmonary vein; and in 5 patients with ASD, PAPVC was identified only after the ASD closure. CONCLUSIONS: This large series provides descriptive and hemodynamic features for isolated and ASD-associated PAPVCs. Anomalous isolated right upper pulmonary vein may cause a significant shunt (Qp/Qs >1.5). PAPVC associated with sinus venosus and secundum ASDs might be more complex than a single anomalous pulmonary vein and missed before ASD correction.


Assuntos
Comunicação Interatrial/diagnóstico por imagem , Hemodinâmica , Imagem Cinética por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Bases de Dados Factuais , Feminino , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/anormalidades , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Adulto Jovem
5.
J Am Heart Assoc ; 10(14): e020692, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34259012

RESUMO

Background Despite correction of the atrial septal defect (ASD), patients experience atrial fibrillation frequently and have increased morbidity and mortality. We examined physical capacity, cardiac performance, and invasive hemodynamics in patients with corrected ASD. Methods and Results Thirty-eight corrected patients with isolated secundum ASD and 19 age-matched healthy controls underwent right heart catheterization at rest and during exercise with simultaneous expired gas assessment and echocardiography. Maximum oxygen uptake was comparable between groups (ASD 32.7±7.7 mL O2/kg per minute, controls 35.2±7.5 mL O2/kg per minute, P=0.3), as was cardiac index at both rest and peak exercise. In contrast, pulmonary artery wedge v wave pressures were increased at rest and peak exercise (rest: ASD 14±4 mm Hg, controls 10±5 mm Hg, P=0.01; peak: ASD 25±9 mm Hg, controls 14±9 mm Hg, P=0.0001). The right atrial v wave pressures were increased at rest but not at peak exercise. The transmural filling pressure gradient (TMFP) was higher at peak exercise among patients with ASD (10±6 mm Hg, controls 7±3 mm Hg, P=0.03). One third of patients with ASD demonstrated an abnormal hemodynamic exercise response defined as mean pulmonary artery wedge pressure ≥25 mm Hg and/or mean pulmonary artery pressure ≥35 mm Hg at peak exercise. These patients had significantly elevated peak right and left atrial a wave pressures, right atrial v wave pressures, pulmonary artery wedge v wave pressures, and transmural filling pressure compared with both controls and patients with ASD with a normal exercise response. Conclusions Patients with corrected ASD present with elevated right and in particular left atrial pressures at rest and during exercise despite preserved peak exercise capacity. Abnormal atrial compliance and systolic atrial function could predispose to the increased long-term risk of atrial fibrillation. Registration Information clinicaltrials.gov. Identifier: NCT03565471.


Assuntos
Função do Átrio Esquerdo/fisiologia , Função do Átrio Direito/fisiologia , Pressão Atrial/fisiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Exercício Físico/fisiologia , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Adulto , Cateterismo Cardíaco/métodos , Ecocardiografia , Teste de Esforço/métodos , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Hemodinâmica/fisiologia , Humanos , Masculino , Período Pós-Operatório , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
7.
BMC Cardiovasc Disord ; 21(1): 348, 2021 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-34294038

RESUMO

BACKGROUND: There is a paucity of published literature describing electrical storm after the correction of uncomplicated atrial septal defect (ASD) in an adult. CASE PRESENTATION: We present a 49-year-old woman with a congenital ASD combined with mild tricuspid regurgitation who denied any history of arrhythmia or other medical history. She suffered from electrical storm (≥ 3 episodes of ventricular tachycardias or ventricular fibrillations) in the early stage after ASD repair with combined tricuspid valvuloplasty. During electrical storm, her electrolytes were within normal ranges and no ischemic electrocardiographic changes were detected, which suggested that retained air embolism or acute coronary thrombosis were unlikely. Additionally, echocardiographic findings and her central venous pressure (5-8 mmHg during the interval between attacks) failed to support the diagnosis of pericardial tamponade. After a thorough discussion, the surgeons conducted an emergent re-exploration and repeated closure of the ASD with combined DeVega's annuloplasty. Eventually, the patient recovered uneventfully, without reoccurring arrhythmias during follow-up. Although we fail to determine the definite cause, we speculate that the causes probably are iatrogenic injury of the conduction system due to a rare anatomic variation, poor intraoperative protection, latent coronary distortion during tricuspid valvuloplasty, or idiopathic or secondary abnormalities of the conduction system. CONCLUSIONS: For most surgeons, performing re-exploration without a known etiology is a difficult decision to make. This case illustrates that re-exploration could be an option when electrical storm occurs in the early stage postoperatively. Nevertheless, surgeons should assess the benefit-risk ratio when taking this unconventional measure.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Frequência Cardíaca , Comunicação Interatrial/cirurgia , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Pessoa de Meia-Idade , Recidiva , Reoperação , Fatores de Risco , Cirurgia de Second-Look , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/prevenção & controle
8.
J Chin Med Assoc ; 84(5): 550-554, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33770054

RESUMO

Transthoracic echocardiography (TTE) is noninvasive but can only be performed intermittently during fluoroscopy. In a prior study, we created a transducer holder device to allow for hemodynamic monitoring in the intensive care unit. The current study is the first instance of the use of a three-dimensional (3D)-printed TTE transducer holder, which is easily customized and personalized to a previous transducer holder at relatively low cost and short production time, to enable continuous TTE monitoring during device closure of an atrial septal defect (ASD) and ventricular septal defect (VSD). There were 14 ASD patients and 9 VSD patients scheduled to undergo device closure. The study's real-time TTE monitoring was performed by using a 3D-printed transducer holder over the course of the entire implantation procedure. There were 23 patients who successfully underwent septal closures using the 3D-printed holder that enabled real-time images over the entire procedure. The median duration for real-time TTE guidance was 15 minutes for the ASD and 36 minutes for the VSD and the median fluoroscopy time was 11 minutes for the ASD and 30 minutes for the VSD. One migrating VSD occluder and one case of aortic regurgitation after occluder deployment were noted by real-time TTE monitoring during the procedure. Our novel 3D-printed transducer holder can provide transesophageal echocardiography-like real-time imaging during device closure of an ASD and a VSD and may become a new alternative method in ASD and VSD closures. It can also prevent radiation exposure for the intervention team who would otherwise need to perform TTE during live fluoroscopy.


Assuntos
Ecocardiografia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Impressão Tridimensional , Transdutores , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Comunicação Interatrial/fisiopatologia , Comunicação Interventricular/fisiopatologia , Humanos , Lactente , Pessoa de Meia-Idade , Adulto Jovem
9.
Ultrasound Med Biol ; 47(6): 1514-1527, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33685744

RESUMO

Using blood speckle tracking (BST) based on high-frame-rate echocardiography (HFRE), we compared right ventricle (RV) flow dynamics in children with atrial septal defects (ASDs) and repaired tetralogy of Fallot (rTOF). Fifty-seven children with rTOF with severe pulmonary insufficiency (PI) (n = 21), large ASDs (n = 11) and healthy controls (CTL, n = 25) were included. Using a flow phantom, we studied the effects of imaging plane and smoothing parameters on 2-D energy loss (EL). RV diastolic EL was similar in ASD and rTOF, but both were greater than in CTL. Locations of high EL were similar in all groups in systole, occurring in the RV outflow tract and around the tricuspid valve leaflets in early diastole. An additional apical early diastolic area of EL was noted in rTOF, corresponding to colliding tricuspid inflow and PI. The flow phantom revealed that EL varied with imaging plane and smoothing settings but that the EL trend was preserved if kept consistent.


Assuntos
Ecocardiografia/métodos , Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/cirurgia , Criança , Pré-Escolar , Dilatação Patológica , Feminino , Ventrículos do Coração/patologia , Humanos , Lactente , Masculino , Fenômenos Físicos , Projetos Piloto , Fluxo Sanguíneo Regional
10.
Clin Res Cardiol ; 110(8): 1270-1279, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33649885

RESUMO

OBJECTIVE: Congenital interatrial shunt can unload the left atrium (LA) and may lower the risk of new-onset heart failure (HF) or atrial fibrillation (AF). We evaluated the risk of new-onset HF or AF in patients with and without interatrial shunt. METHODS: We enrolled 2660 consecutive patients with acute stroke or transient ischemic attack (TIA) who underwent transesophageal echocardiography at Seoul National University Bundang Hospital from January 1, 2006 to December 31, 2018. The primary outcomes were 10-year new-onset HF, new-onset AF, and new-onset HF or AF composite. RESULTS: Overall, 466 (17.5%) patients with an interatrial shunt had smaller E velocity (0.66 ± 0.21 vs. 0.69 ± 0.22 m/s, P = 0.037) and smaller E/e' (9.1 ± 4.0 vs. 10.0 ± 5.0, P = 0.001) than 2194 (82.5%) patients without an interatrial shunt. The 10-year incidence of AF, HF, and AF or HF composite was lower in patients with an interatrial shunt (10-year AF, 11.2 vs. 17.8%, P < 0.001; 10-year HF, 6.2 vs. 10.4%, P = 0.005; 10-year AF or HF composite, 16.5 vs. 23.4%, P = 0.001). In multivariable analysis, the presence of an interatrial shunt was associated with a 38% (HR 0.62, 95% CI 0.40-0.96), 40% (HR 0.60; 95% CI 0.39-0.93), and 26% (HR 0.74; 95% CI 0.57-0.96) reduced risk for new-onset HF, AF, and new-onset HF or AF composite, respectively. CONCLUSION: In patients with interatrial shunt, the risk of AF and HF was lower. Interatrial shunt may be beneficial, and the closure of an interatrial shunt should be performed only in carefully selected patients. An interatrial shunt can unload the left atrium. In patients with stroke or TIA, the presence of an interatrial shunt was associated with a reduced risk for new-onset HF and AF. AF atrial fibrillation, HF heart failure, HR hazard ratio, LA left atrium.


Assuntos
Fibrilação Atrial/fisiopatologia , Átrios do Coração/anormalidades , Insuficiência Cardíaca/fisiopatologia , Comunicação Interatrial/complicações , Idoso , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
11.
J Interv Cardiol ; 2021: 8846656, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33536856

RESUMO

BACKGROUND: The age of candidates for device closure of atrial septal defect (ASD) has been increasing. Thus, concerns exist about dyspnea aggravation or atrial fibrillation development after device closure due to augmentation of left ventricular (LV) and left atrial (LA) preload. This study aimed to examine patterns and determinants of serial pulmonary arterial pressure and left ventricular filling pressure changes after device closure of ASD. METHODS: Among the 86 consecutive patients who underwent percutaneous device closure of ASD, those with end-stage renal disease or those without pre- or postprocedural Doppler data were excluded. The clinical, transesophageal, and transthoracic echocardiographic findings of 78 patients were collected at baseline, one-day postprocedure, and one-year follow-up. RESULTS: The mean age of study patients was 49.8 ± 15.0 years, and the average maximal defect diameter and device size were 20.2 ± 6.0 mm and 23.8 ± 6.4 mm. Four patients (5.6%) underwent new-onset atrial fibrillation, and five patients (6.4%) took diuretics within one-year after closure. Some patients (n = 21; 27%) exhibited paradoxically increased tricuspid regurgitant velocity (TRV) one-day postprocedure; they also were older with lower e', glomerular filtration rate, and LV ejection fraction and a higher LA volume index. However, even in these patients, TRV deceased below baseline levels one-year later. Both E/e' and LA volume index significantly increased immediately after device closure, but all decreased one-year later. Larger defect size and higher TRV were significantly correlated with immediate E/e' elevation. CONCLUSION: In older, renal, diastolic, and systolic dysfunctional patients with larger LA and scheduled for larger device implantation, peri-interventional preload reduction therapy would be beneficial.


Assuntos
Fibrilação Atrial , Cateterismo Cardíaco , Comunicação Interatrial/cirurgia , Complicações Pós-Operatórias , Dispositivo para Oclusão Septal , Disfunção Ventricular Esquerda/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Feminino , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Pressão Propulsora Pulmonar , Insuficiência Renal/epidemiologia , Risco Ajustado , Fatores de Risco , Resultado do Tratamento
12.
BMC Cardiovasc Disord ; 21(1): 12, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33413087

RESUMO

BACKGROUND: Although most cases of atrial septal defect (ASD) are sporadic, familial cases have been reported, which may be caused by mutation of transcription factor GATA binding protein 4 (GATA4). Herein we combined whole-exome sequencing and bioinformatics strategies to identify a novel mutation in GATA4 accounting for the etiology in a Chinese family with ASD. METHODS: We identified kindred spanning 3 generations in which 3 of 12 (25.0%) individuals had ASD. Punctilious records for the subjects included complete physical examination, transthoracic echocardiography, electrocardiograph and surgical confirming. Whole-exome capture and high-throughput sequencing were performed on the proband III.1. Sanger sequencing was used to validate the candidate variants, and segregation analyses were performed in the family members. RESULTS: Direct sequencing of GATA4 from the genomic DNA of family members identified a T-to-C transition at nucleotide 929 in exon 5 that predicted a methionine to threonine substitution at codon 310 (M310T) in the nuclear localization signal (NLS) region. Two affected members (II.2 and III.3) and the proband (III.1) who was recognized as a carrier exhibited this mutation, whereas the other unaffected family members or control individuals did not. More importantly, the mutation GATA4 (c.T929C: p.M310T) has not been reported previously in either familial or sporadic cases of congenital heart defects (CHD). CONCLUSIONS: We identified for the first time a novel M310T mutation in the GATA4 gene that is located in the NLS region and leads to family ASD with arrhythmias. However, the mechanism by which this pathogenic mutation contributes to the development of heart defect and tachyarrhythmias remains to be ascertained.


Assuntos
Arritmias Cardíacas/genética , Fator de Transcrição GATA4/genética , Comunicação Interatrial/genética , Mutação , Adolescente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Criança , Pré-Escolar , Biologia Computacional , Análise Mutacional de DNA , Feminino , Predisposição Genética para Doença , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Hereditariedade , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem , Fenótipo , Sequenciamento do Exoma
13.
BMJ Case Rep ; 14(1)2021 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-33431524

RESUMO

A 34-year-old woman was seen in the emergency department for shortness of breath and chest pain. During a pandemic, it is easy to 'think horses and not zebras', and with a patient presenting with the classic coronavirus symptoms it would have been easy to jump to that as her diagnosis. After a careful history and examination, it became clear that there was another underlying diagnosis. Chest X-ray, echocardiogram and CT scan revealed marked right ventricular dilatation and pulmonary hypertension, alongside a persistent left superior vena cava (PLSVC). Further investigation with cardiac MRI and coronary angiography at a tertiary centre demonstrated that she not only have a PLSVC but also a partial anomalous pulmonary venous drainage and sinus venosus atrial septal defect. This case highlights the importance of considering all differentials and approaching investigations in a logical manner.


Assuntos
COVID-19/diagnóstico , Dor no Peito/fisiopatologia , Dispneia/fisiopatologia , Comunicação Interatrial/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Hipertrofia Ventricular Direita/diagnóstico por imagem , Veia Cava Superior Esquerda Persistente/diagnóstico por imagem , Síndrome de Cimitarra/diagnóstico por imagem , Adulto , Cateterismo Cardíaco , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Diagnóstico Diferencial , Dilatação Patológica/complicações , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/fisiopatologia , Dispneia/etiologia , Ecocardiografia , Eletrocardiografia , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/fisiopatologia , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Hipertrofia Ventricular Direita/complicações , Hipertrofia Ventricular Direita/fisiopatologia , Imageamento por Ressonância Magnética , Veia Cava Superior Esquerda Persistente/complicações , Veia Cava Superior Esquerda Persistente/fisiopatologia , SARS-CoV-2 , Síndrome de Cimitarra/complicações , Síndrome de Cimitarra/fisiopatologia , Tomografia Computadorizada por Raios X , Pressão Ventricular
14.
Heart Vessels ; 36(5): 710-716, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33386922

RESUMO

Transcatheter atrial septal defect (ASD) closures using an Amplatzer Septal Occluder (ASO) have been widely performed. Compared to children, we sometimes experience late recovery of exercise performance in adult patients. Our study aimed to evaluate the change in the cardiopulmonary exercise capacity in asymptomatic or mildly symptomatic adult patients after a transcatheter ASD closure using an ASO. The subjects consisted of 29 patients (age 39.5 ± 13.6 years) that underwent cardiopulmonary exercise testing (CPX) before, 3, 6, and 12 months after a transcatheter secundum ASD closure using an ASO. The peak oxygen consumption (peak VO2), anaerobic threshold (AT), and slope of the correlation between the ventilation and carbon dioxide production (VE/VCO2 slope) were evaluated. We also evaluated the left-ventricular end-diastolic diameter (LVEDD), right-ventricular end-diastolic dimension (RVEDD) by echocardiography, and hemodynamic values by cardiac catheterization before the ASO procedure. The peak VO2 did not show any improvement 3 months after the ASO procedure; however, a significant improvement was displayed 6 and 12 months (baseline: 23.4 ± 6.3, 3 months: 23.6 ± 6.4, 6 months: 25.1 ± 5.6, 12 months: 26.4 ± 5.3 mL/kg/min; p < 0.001) after the ASO. The LVEDD (before: 38.1 ± 3.6, 3 months: 43.4 ± 3.4 mm; p < 0.001) and RVEDD (before: 33.6 ± 5.3, 3 months: 26.3 ± 2.6 mm; p < 0.001) on echocardiography quickly improved 3 months after the ASO. Although the LVEDD and RVEDD normalized 3 months after the ASO, the peak VO2 still decreased; however, the peak VO2 improved to almost a normal range 6 months after the ASO.


Assuntos
Cateterismo Cardíaco/métodos , Tolerância ao Exercício/fisiologia , Comunicação Interatrial/cirurgia , Recuperação de Função Fisiológica , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Adulto Jovem
15.
Int J Cardiovasc Imaging ; 37(3): 903-912, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33047179

RESUMO

To clarify the impact on left ventricular (LV) function of percutaneous atrial septal defect (ASD) closure in adult patients. Echocardiograms of 46 patients (52 ± 18 years) who underwent ASD closure with a significant left-to-right shunt obtained before and 1 month after the procedure were retrospectively analyzed. Functional parameters were obtained by 2-dimensional speckle-tracking imaging. Global longitudinal strain and strain rate at early diastole (SRe) was calculated from the three standard apical views, while circumferential and radial parameters were calculated from basal, middle, and apical LV short-axis views. Along with a diminished right ventricular (RV) volume, the LV volume and ejection fraction increased (end-diastolic volume: 61 ± 12 to 76 ± 15 mL, p < 0.001; and 63% ± 4 to 64% ± 4% p = 0.03; respectively). Both global strain and SRe was augmented only in the circumferential direction (- 16.2% ± 2.9% to - 19.8% ± 2.8%; and 1.07 ± 0.29 to 1.34 ± 0.28 s-1, both p < 0.001). Augmentation of circumferential SRe correlated with both the changes in and the pre-procedural value of diastolic LV eccentricity index (r = - 0.57, p < 0.001; and r = 0.37, p = 0.01; respectively), a morphological parameter of RV volume overload. Following ASD closure in adults, both LV systolic and diastolic function could favorably change in the circumferential direction, and the degree of diastolic functional change is associated with RV volume overload, i.e., severity of ventricular interdependence.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Comunicação Interatrial/terapia , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
World J Pediatr Congenit Heart Surg ; 11(6): 733-741, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33164679

RESUMO

BACKGROUND: Repair of superior sinus venosus defect with high partially anomalous pulmonary venous connection (PAPVC) using an intracardiac baffle may be complicated by systemic or pulmonary venous pathway obstruction and sinus nodal dysfunction (SND). Our surgical strategy for repair of all types of superior sinus venosus defect has evolved chiefly to avoid the abovementioned complications and preserving the growth potential of the superior cavoatrial junction. METHODS: Between 2007 and 2019, fifty consecutive patients aged 2 to 60 (mean, 17.6±16.7) years underwent repair of superior sinus venosus defect using the double-barrel technique as described. The anomalous pulmonary veins drained into the superior cavoatrial junction in 17 patients and more than 2 cm above the cavoatrial junction in 33 patients. RESULTS: There were no early or late deaths and no reoperations. At a mean follow-up of 103.9 (±50.2) months, all survived the operation, and actuarial freedom from SND was 97.9% (±standard error, 0.02%; 95% CI: 0.86-0.99). No patient had systemic or pulmonary venous pathway obstruction. A permanent pacemaker was required in one (2%) patient for sick sinus syndrome. CONCLUSIONS: The double-barrel method is an expedient, safe, and effective technique in superior sinus venosus defect. It provides dual drainage of superior vena cava preserving the superior cavoatrial junction without causing systemic or pulmonary venous pathway obstruction and can be utilized in all cases including those with high PAPVC. Preservation of the cavoatrial junction and use of autogenous atrial tissue for systemic venous pathway avoids SND and preserves growth potential.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Comunicação Interatrial/cirurgia , Circulação Pulmonar/fisiologia , Veias Pulmonares/anormalidades , Veia Cava Superior/cirurgia , Adolescente , Adulto , Cateterismo Cardíaco , Criança , Pré-Escolar , Angiografia por Tomografia Computadorizada , Ecocardiografia , Feminino , Seguimentos , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Adulto Jovem
17.
BMC Cardiovasc Disord ; 20(1): 444, 2020 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-33045999

RESUMO

BACKGROUND: One-stop occlusion, which is defined as the combination of atrial septal defect [ASD] or patent foramen ovale [PFO] occlusion and left atrial appendage [LAA] closure, in patients with ASD/PFO and atrial fibrillation (AF) has not yet been investigated systematically. This study aimed to evaluate the safety and efficacy of one-stop occlusion in the treatment of adult patients with ASD/PFO and AF. METHODS: Inpatients with AF and ASD/PFO were recruited between August 2014 and April 2019. Preoperatively, transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) were conducted to identify the ASD/PFO size and margin, presence of thrombus in the LAA, and LAA orifice width and depth at 0°, 45°, 90°, and 135°. After confirmation of the indications of LAA closure (LAAC) and ASD/PFO occlusion, the procedures were performed simultaneously under general anesthesia. Oral anticoagulants were administered for 45-60 days, followed with regular evaluation of TTE and TEE. RESULTS: Forty-nine patients (age, 65.6 ± 9.6 years) were recruited in this study, including 24 patients with ASD and 25 patients with PFO. They were treated with LAAC and ASD/PFO occlusion successfully. The mean ASD size and mean diameter of the ASD occluders were 14.2 ± 7.7 and 25.4 ± 8.5 mm, respectively. The mean PFO size was 3.5 ± 0.4 mm. The mean maximal LAA orifice width and depth were 20.5 ± 3.4 and 28.3 ± 3.6 mm, respectively. All patients were implanted with a Watchman device (diameter, 27.1 ± 2.9 mm). Postoperatively, all patients took anticoagulants orally for 45-60 days, and their mean postoperative follow-up duration was 29.0 ± 12.1 months. Postoperative TEE showed that all had normal positioning of the LAA and ASD/PFO occluders. At 45-60 days after operation, TEE showed that the LAA and ASD/PFO occluder were in the normal position; however, two patients who took warfarin and novel oral anticoagulants, respectively, have developed occluder thrombosis. After adjusted anticoagulant therapy, TEE showed that the thrombus disappeared at 6 months after operation. CONCLUSION: One-stop occlusion is safe and effective for the treatment of adult patients with ASD/PFO and AF. It is also feasible to administer warfarin or novel oral anticoagulants after operation.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Forame Oval Patente/terapia , Comunicação Interatrial/terapia , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Esquema de Medicação , Estudos de Viabilidade , Feminino , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Frequência Cardíaca , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento
18.
Open Heart ; 7(2)2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33020256

RESUMO

AIMS: Objective of this study was to evaluate the feasibility of the non-invasive dye dilution method to quantify shunt size related to atrial septal defects (ASD).The diagnostic accuracy of shunt size determination in ASD's has been suboptimal with common non-invasive methods. We have previously developed a cost-effective and time-effective non-invasive dye dilution method. In this method, the indocyanine green solution is injected into the antecubital vein and the appearance of the dye is detected with an earpiece densitometer. METHODS AND RESULTS: We studied 192 patients with an ASD. Mean pulmonary blood flow/systemic blood flow (Qp/Qs) was measured with dye dilution technique and compared with following methods: Fick's invasive oximetry (n=49), transoesophageal echocardiography (TEE) measuring ASD size (n=143) and cardiac MR (CMR) (n=9).For the first 49 patients, Qp/Qs was 2.05±0.70 with the Fick's invasive oximetry and 2.12±0.68 with dye dilution method with an excellent correlation between the two methods (R=0.902, p<0.001). In the second study sample, the ASD size by TEE was 15±6 mm on average, and the mean Qp/Qs 2.16±0.65 measured with dye dilution method with a good correlation between the methods (R=0.674, p<0.001). Qp/Qs measured with CMR was 1.87±0.40 resulting in a good correlation with the dye dilution method (R=0.696, p=0.037). CONCLUSION: The dye dilution method with earpiece densitometer recording is a clinically feasible and reliable method to assess shunt size in ASDs.


Assuntos
Corantes/administração & dosagem , Comunicação Interatrial/diagnóstico , Hemodinâmica , Técnicas de Diluição do Indicador , Verde de Indocianina/administração & dosagem , Adulto , Idoso , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Comunicação Interatrial/fisiopatologia , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Oximetria , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
Am J Physiol Heart Circ Physiol ; 319(5): H938-H947, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32886004

RESUMO

In patients with heart failure, atrial septal defect (ASD) closure has a risk of inducing life-threatening acute pulmonary edema. The objective of this study was to develop a novel framework for quantitative prediction of hemodynamics after ASD closure. The generalized circulatory equilibrium comprises right and left cardiac output (CO) curves and pulmonary and systemic venous return surfaces. We incorporated ASD into the framework of circulatory equilibrium by representing ASD shunt flow (QASD) by the difference between pulmonary flow (QP) and systemic flow (QS). To examine the accuracy of prediction, we created ASD in six dogs. Four weeks after ASD creation, we measured left atrial pressure (PLA), right atrial pressure (PRA), QP, and Qs before and after ASD balloon occlusion. We then predicted postocclusion hemodynamics from measured preocclusion hemodynamics. Finally, we numerically simulated hemodynamics under various ASD diameters while changing left and right ventricular function. Predicted postocclusion PLA, PRA, and QS from preocclusion hemodynamics matched well with those measured [PLA: coefficient of determination (r2) = 0.96, standard error of estimate (SEE) = 0.89 mmHg, PRA: r2 = 0.98, SEE = 0.26 mmHg, QS: r2 = 0.97, SEE = 5.6 mL·min-1·kg-1]. A simulation study demonstrated that ASD closure increases the risk of pulmonary edema in patients with impaired left ventricular function and normal right ventricular function, indicating the importance of evaluation for the balance between right and left ventricular function. ASD shunt incorporated into the generalized circulatory equilibrium accurately predicted hemodynamics after ASD closure, which would facilitate safety management of ASD closure.NEW & NOTEWORTHY We developed a framework to predict the impact of atrial septal defect (ASD) closure on hemodynamics by incorporating ASD shunt flow into the framework of circulatory equilibrium. The proposed framework accurately predicted hemodynamics after ASD closure. Patient-specific prediction of hemodynamics may be useful for safety management of ASD closure.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Comunicação Interatrial/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Complicações Pós-Operatórias/fisiopatologia , Animais , Cães , Comunicação Interatrial/cirurgia , Complicações Pós-Operatórias/epidemiologia
20.
BMC Cardiovasc Disord ; 20(1): 411, 2020 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-32917130

RESUMO

BACKGROUND: Factors affecting heart rate variability (HRV) in patients with atrial septal defect (ASD) have not been clarified. This study sought to identify those factors and establish a preliminary risk model. METHODS: A total of 154 patients with ASD who underwent transcatheter closure and met the study requirements were analyzed in this study. Moreover, 26 patients with patent foramen ovale (PFO) were enrolled in our study as a control group. All patients underwent echocardiography and ambulatory electrocardiography before and one day after the procedure. RESULTS: The standard deviation of all normal-to-normal (NN) intervals (SDNN) and the standard deviation of the averages of the NN intervals in all 5 min segments of the entire recording (SDANN) were significantly higher and the heart rate was lower after closure than before closure in patients with ASD (SDNN: 6.08, 95% CI 3.00 to 9.15, p < 0.001; SDANN: 7.57, 95% CI 4.50 to 10.64, p < 0.001; heart rate: -1.17, 95% CI - 2.86 to - 0.48, p = 0.006). Multiple regression analyses indicated that age, sex, defect diameter, heart rate and diabetes were significantly associated with HRV indices (SDNN: R2 = 0.415; P < 0.001). SDNN and SDANN had obvious correlations with right ventricular systolic pressure (SDNN: R = - 0.370, p < 0.001; SDANN: R = - 0.360, p < 0.001). CONCLUSIONS: Factors affecting HRV in patients with ASD include age, sex, heart rate, defect size and diabetes. Furthermore, right ventricular systolic pressure plays an important role in the change in HRV.


Assuntos
Cateterismo Cardíaco , Eletrocardiografia Ambulatorial , Frequência Cardíaca , Comunicação Interatrial/terapia , Adulto , Estudos de Casos e Controles , Feminino , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...